{"title":"Salinity, TDS \u0026 pH Pen Testers","description":"\u003cp data-start=\"193\" data-end=\"763\"\u003eGet fast, accurate water readings with our range of digital pen testers for aquariums. Designed for both freshwater and marine setups, these pens measure essential parameters like salinity, TDS (total dissolved solids), and pH with precision and ease. Ideal for reef tanks, planted tanks, shrimp setups, and general water quality monitoring, these handheld devices provide instant results and help maintain perfect conditions for fish, plants, and corals. Reliable, portable, and simple to use. perfect for every aquarist.\u003c\/p\u003e","products":[{"product_id":"red-sea-seawater-refractometer","title":"Red Sea Seawater Refractometer","description":"\u003cdiv\u003e\n\u003ch1\u003eSEAWATER REFRACTOMETER\u003c\/h1\u003e\n\u003ch2\u003eHigh-Accuracy Seawater Refractometer\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eRed Sea’s Seawater Refractometer offers exceptional accuracy, for measuring the absolute salinity of seawater at a temperature of 25oC\/77 0F.\u003c\/h3\u003e\n\u003cp\u003eMost refractometers used within the aquarium hobby are not specifically designed for reef aquariums and use an algorithm for the measurement of brine (NaCl – rather than seawater) and at a temperature of 15oC\/59 0F rather than 25oC\/77 0F. Thus, a measurement deviation of up to 1.5ppt is possible, which can have a significant adverse effect on coral growth and coloration.\u003c\/p\u003e\n\u003ch3 class=\"title16 title18\"\u003eMain features of Red Sea’s Seawater Refractometer include:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirectly reads the\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eabsolute\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb\u003esalinity\u003c\/b\u003e\u003cstrong\u003e of\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eseawater\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eat\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e25\u003csup\u003e°\u003c\/sup\u003eC\/\u003c\/b\u003e\u003cb\u003e77\u003csup\u003e\u003cspan\u003e \u003c\/span\u003e0\u003c\/sup\u003eF\u003c\/b\u003e  ( No need for seawater or temperature compensation factors)\u003c\/li\u003e\n\u003cli\u003eSpecifically designed for the ionic content of seawater (NSW) for more accurate salinity measurement (industry standard refractometers are calibrated for salt brine ).\u003c\/li\u003e\n\u003cli\u003eCalibrated for seawater (NSW) at 25\u003csup\u003eo\u003c\/sup\u003eC\/77\u003csup\u003eo\u003c\/sup\u003eF, the normal temperature range for reef aquariums\u003cbr\u003e(most standard refractometers are calibrated at 15\u003csup\u003eo\u003c\/sup\u003eC\/59\u003csup\u003eo\u003c\/sup\u003eF ).\u003c\/li\u003e\n\u003cli\u003eEasier to read, higher resolution display, focussed to the relevant range for reef aquariums of up to 40ppt\u003c\/li\u003e\n\u003cli\u003eIncludes Integrated Automatic  Temperature Compensation (ATC) for accurate measurement at standard ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"title16\"\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3 class=\"title16 title18\"\u003e\u003cspan\u003eRed Sea’s Refractometer display\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PPT scale on Red Sea’s Seawater refractometer is calculated using an algorithm for seawater and therefore will give a reading of the \u003cb\u003eAbsolute Salinity\u003c\/b\u003e of seawater.\u003c\/p\u003e\n\u003cp\u003eThe PPT scale on regular salinity refractometers are calculated using an algorithm for Brine. Using a Brine refractometer for Seawater will give an error of approximately 1.5ppt in the salinity reading.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cimg loading=\"lazy\" class=\"alignnone\" title=\"Red Sea’s Seawater salinity refractometer\" src=\"https:\/\/g1.redseafish.com\/wp-content\/uploads\/2014\/02\/Red-Sea-Refratometer.jpg\" alt=\"Red Sea’s Seawater refractometer red sea seawater refractometer. salinity test for saltwater aquariums\" width=\"373\" height=\"233\"\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/g1.redseafish.com\/wp-content\/uploads\/2014\/02\/refractometer.jpg\"\u003e\u003cimg loading=\"lazy\" src=\"https:\/\/g1.redseafish.com\/wp-content\/uploads\/2014\/02\/refractometer.jpg\" alt=\"refractometer\" width=\"373\" height=\"233\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eRed Sea’s Seawater Refractometer display\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical Salinity Refractometer display\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch4 class=\"title18 title16\"\u003eAbout Salinity\u003c\/h4\u003e\n\u003ch4 class=\"title18 title16\"\u003eSalinity is a general term describing the concentration of salt in water. However, solutions of different type of salts have different refractive indexes.\u003c\/h4\u003e\n\u003cp\u003eBrine is a solution of Sodium Chloride (table salt) that contains 2 chemical elements.\u003c\/p\u003e\n\u003cp\u003eSeawater contains approximately 70 chemical elements that include Calcium, Magnesium, Potassium etc. in addition to the Sodium Chloride.\u003c\/p\u003e\n\u003cp\u003eSeawater and Brine of the same salinity (i.e. the same weight of salt\/liter) have different refractive indexes and will give different salinity readings if measured on the same refractometer.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 class=\"title18 title16\"\u003eRefraction \u0026amp; refractive index\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eAll transparent materials such as liquids refract (distort) light.\u003c\/p\u003e\n\u003cp\u003eAll transparent materials refract light differently and have what is called a “refractive index” which means how much a particular material distorts light.\u003c\/p\u003e\n\u003cp\u003eDifferent concentrations of the same liquid have different refractive indexes.\u003c\/p\u003e\n\u003cp\u003eThe scale of a refractometer is calculated by using a mathematical algorithm that relates the measured refraction to its concentration for a specific liquid.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 class=\"title18 title16\"\u003eRefractive index and temperature\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe refractive index of liquids change with temperature and therefore has a major effect on measuring salinity with a refractometer.\u003c\/p\u003e\n\u003cp\u003eThe algorithm for defining the PPT (and S.G.) scale for a refractometer is calculated for a specific temperature.\u003c\/p\u003e\n\u003cp\u003ePPT readings from refractometers that are not calibrated for reef aquariums (i.e. 25\u003cb\u003e\u003csup\u003eo\u003c\/sup\u003e\u003c\/b\u003eC) need to be adjusted according to a conversion table to give the actual PPT at the aquarium temperature. This is often a cause for misinterpretation of refractometer readings.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor example\u003c\/span\u003e, using a seawater refractometer calibrated at 20\u003cb\u003e\u003csup\u003eo\u003c\/sup\u003e\u003c\/b\u003eC will give a PPT reading that is approximately 1-1.5ppt lower than the absolute salinity of the same water sample at the normal aquarium temperature of 25\u003cb\u003e\u003csup\u003eo\u003c\/sup\u003e\u003c\/b\u003eC.\u003c\/p\u003e\n\u003ch4 class=\"title16\"\u003e\u003cstrong\u003eTherefore, Red Sea’s Seawater Refractometer calibrated at 25\u003csup\u003e°\u003c\/sup\u003eC\/77\u003csup\u003e\u003cspan\u003e \u003c\/span\u003e0\u003c\/sup\u003eF directly reads the absolute salinity of seawater with no need for temperature compensation factor)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/div\u003e","brand":"Red Sea","offers":[{"title":"Default Title","offer_id":44736192905392,"sku":"7290100774830","price":124.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/4133\/1120\/files\/RED197.jpg?v=1757128713"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/4133\/1120\/collections\/Salinity_Ph_TDS.png?v=1763001423","url":"https:\/\/auburnaquariumandterrarium.com.au\/collections\/salinity-tds-ph-pen-testers.oembed","provider":"Auburn Aquarium and Terrarium","version":"1.0","type":"link"}